 Quantité minimale : 1
| Product ID | P11147 | 
| Maximum values | Ui = 13.65 V / li = 200 mA / Pi = 0.69 W / Ci = 0.45 nF / Li = 1.80 µH | 
| Protection [EN 60529] | IP 67 | 
| Material housing | stainless steel AISI 316 Ti, brass | 
| Compressive strength | 60 bar | 
| Sensor length L | 40 mm | 
| ATEX marking gas | Ex II 2 G Ex ib IIC T6...T3 Gb | 
| Electrical connection | 2 m PUR-cable, 4x0.25 mm² | 
| Material sensor touched by medium | stainless steel AISI 316 Ti | 
| Reaction time typ. | 2 s (1 ... 13 s) | 
| Temperature range dust-Ex | -20 ... 85 °C | 
| Detection range Oil | 3 ... 200 cm/s | 
| Process connection | NPT1/2 | 
| Output | output with separate Amplifier | 
| TYPE | ST 104 K | 
| Associated amplifiers | SZAb 400 EX-GR, SZAb 400 EX-WR115, SZAb 400 EX-WR230, SZAb 400 EX-GA | 
| Temperature range in T4 | -20 ... 85 °C | 
| Temperature range in T5 | -20 ... 55 °C | 
| ATEX Certificate | TÜV 97 ATEX 1218 | 
| Temperature range in T6 | -20 ... 40 °C | 
| Ex area uf use | Zone 1, Zone 21 | 
| Temperature range in T3 | -20 ... 85 °C | 
| Detection range water | 1 ... 100 cm/s | 
| ATEX Marking dust | Ex II 2 D Ex ib IIIC T125°C Db | 
| Medium | Water, oil | 
| Start-up time typ. | 8 s (2 ... 18 s) | 
| Note | probe with longer cable available on request |