Quantité minimale : 1
| Product ID | P10623 |
| Accessories (in scope of delivery) | 2 x gasket G1/2 AFM 34 |
| Associated amplifiers | SKM 420, SKM 522, SKZ 400 |
| Protection [EN 60529] | IP 68 |
| Material housing | metal-ceramic coating, titan |
| Compressive strength | 100 bar |
| Sensor length L | 34 mm |
| Medium temperature | -20 ... 80 °C |
| Electrical connection | 2 m FEP-cable 4x0.25 mm² |
| Detection range water | 1 ... 150 cm/s |
| Material sensor touched by medium | titan, metall-ceramic coating |
| Temperature gradient fluids | 250 K/min |
| Reaction time typ. | 2 s (1 ... 13 s) |
| Detection range Oil | 3 ... 300 cm/s |
| Ambient temperature | -20 ... 80 °C |
| Medium | Water, oil |
| Process connection | G1/2 |
| Start-up time typ. | 8 s (2 ... 15 s) |
| Note | probe with longer cable available on request, temperature range 10 °C...120 °C on request |
| TYPE | STA 421 K-B3 |