| Product ID | P11207 |
| Accessories (in scope of delivery) | 2 x gasket G1/2 AFM 34 |
| Maximum values | Ui = 13.65 V / li = 200 mA / Pi = 0.69 W / Ci = 0.45 nF / Li = 1.80 µH |
| Protection [EN 60529] | IP 67 |
| Material housing | stainless steel AISI 316 Ti, brass, PA |
| Compressive strength | 10 bar |
| Sensor length L | 48 mm |
| ATEX marking gas | Ex II 1 G Ex ia IIC T6…T3 Ga |
| Electrical connection | M12 connector |
| Material sensor touched by medium | stainless steel AISI 316 Ti |
| Reaction time typ. | 3 s (2 ... 30 s) |
| Temperature range dust-Ex | -20 ... 85 °C |
| Process connection | G1/2 |
| Output | output with separate Amplifier |
| Marking gas Ex for partition wall mounting | Ex II 1/2 G Ex ia IIC T6…T3 Ga/Gb |
| TYPE | STS 215 S |
| Associated amplifiers | SZAb 400 EX-GR, SZAb 400 EX-WR115, SZAb 400 EX-WR230, SZAb 400 EX-GA |
| Temperature range in T4 | -20 ... 85 °C |
| Temperature range in T5 | -20 ... 50 °C |
| ATEX Certificate | TÜV 98 ATEX 1298 X |
| Temperature range in T6 | -20 ... 35 °C |
| Detection range air | 2 ... 25 m/s |
| Ex area uf use | installation in partition wall Zone 0/1, Zone 0, Zone 20 |
| Temperature range in T3 | -20 ... 85 °C |
| ATEX Marking dust | Ex II 1 D Ex ia IIIC T130°C Da |
| Medium | air |
| Start-up time typ. | 5 ... 20 s |