 Quantité minimale : 1
| Product ID | P11409 | 
| Accessories (in scope of delivery) | 2 x gasket G1/4 AFM 34 | 
| Maximum values | Ui = 13.65 V / li = 200 mA / Pi = 0.69 W / Ci = 0.45 nF / Li = 1.80 µH | 
| Protection [EN 60529] | IP 67 | 
| Material housing | stainless steel AISI 316 Ti, brass | 
| Compressive strength | 60 bar | 
| Sensor length L | 25 mm | 
| ATEX marking gas | Ex II 1 G Ex ia IIC T6…T3 Ga | 
| Electrical connection | 2 m FEP-cable 4x0.25 mm² | 
| Material sensor touched by medium | stainless steel AISI 316 Ti | 
| Reaction time typ. | 2 s (1 ... 13 s) | 
| Temperature range dust-Ex | -20 ... 85 °C | 
| Detection range Oil | 3 ... 200 cm/s | 
| Process connection | G 1/4 | 
| Output | output with separate Amplifier | 
| Marking gas Ex for partition wall mounting | Ex II 1/2 G Ex ia IIC T6…T3 Ga/Gb | 
| TYPE | STS 101 KH | 
| Associated amplifiers | SZAb 400 EX-GR, SZAb 400 EX-WR115, SZAb 400 EX-WR230, SZAb 400 EX-GA | 
| Temperature range in T4 | 10 ... 90 °C | 
| Temperature range in T5 | 10 ... 55 °C | 
| ATEX Certificate | TÜV 98 ATEX 1298 X | 
| Temperature range in T6 | 10 ... 40 °C | 
| Ex area uf use | installation in partition wall Zone 0/1, Zone 0, Zone 20 | 
| Temperature range in T3 | 10 ... 120 °C | 
| Detection range water | 1 ... 100 cm/s | 
| ATEX Marking dust | Ex II 1 D Ex ia IIIC T125°C Da | 
| Medium | Water, oil | 
| Start-up time typ. | 8 s (2 ... 18 s) | 
| Note | probe with longer cable available on request |